* shell: warn in volume.list when a volume id spans collections A reused volume id, the result of the master handing out an id already used by another collection (for example after losing its max-volume-id counter on restart), makes collection.delete destroy the wrong collection's data and makes any bare-id lookup, move, or vacuum ambiguous. volume.list now scans the full topology and warns on ids present in more than one collection so the clash is visible before any destructive operation. * volume.list: track duplicate ids lazily, sort with slices.Sort Allocate the per-id collection set only on the first cross-collection clash instead of one set per volume, so allocations scale with duplicates rather than the volume count.
282 lines
9.9 KiB
Go
282 lines
9.9 KiB
Go
package shell
|
|
|
|
import (
|
|
"bytes"
|
|
"flag"
|
|
"fmt"
|
|
|
|
"github.com/seaweedfs/seaweedfs/weed/storage/erasure_coding"
|
|
"github.com/seaweedfs/seaweedfs/weed/storage/types"
|
|
"github.com/stretchr/testify/assert"
|
|
|
|
//"google.golang.org/protobuf/proto"
|
|
"strconv"
|
|
"strings"
|
|
"testing"
|
|
|
|
"github.com/golang/protobuf/proto"
|
|
|
|
"github.com/seaweedfs/seaweedfs/weed/pb/master_pb"
|
|
)
|
|
|
|
func TestParsing(t *testing.T) {
|
|
topo := parseOutput(topoData)
|
|
|
|
assert.Equal(t, 5, len(topo.DataCenterInfos))
|
|
|
|
topo = parseOutput(topoData2)
|
|
|
|
dataNodes := topo.DataCenterInfos[0].RackInfos[0].DataNodeInfos
|
|
assert.Equal(t, 14, len(dataNodes))
|
|
diskInfo := dataNodes[0].DiskInfos[""]
|
|
assert.Equal(t, 1559, len(diskInfo.VolumeInfos))
|
|
assert.Equal(t, 6740, len(diskInfo.EcShardInfos))
|
|
|
|
}
|
|
|
|
// TODO: actually parsing all fields would be nice...
|
|
func parseOutput(output string) *master_pb.TopologyInfo {
|
|
lines := strings.Split(output, "\n")
|
|
var topo *master_pb.TopologyInfo
|
|
var dc *master_pb.DataCenterInfo
|
|
var rack *master_pb.RackInfo
|
|
var dn *master_pb.DataNodeInfo
|
|
var disk *master_pb.DiskInfo
|
|
for _, line := range lines {
|
|
line = strings.TrimSpace(line)
|
|
parts := strings.Split(line, " ")
|
|
switch parts[0] {
|
|
case "Topology":
|
|
if topo == nil {
|
|
topo = &master_pb.TopologyInfo{
|
|
Id: parts[1],
|
|
}
|
|
}
|
|
case "DataCenter":
|
|
if dc == nil {
|
|
dc = &master_pb.DataCenterInfo{
|
|
Id: parts[1],
|
|
}
|
|
topo.DataCenterInfos = append(topo.DataCenterInfos, dc)
|
|
} else {
|
|
dc = nil
|
|
}
|
|
case "Rack":
|
|
if rack == nil {
|
|
rack = &master_pb.RackInfo{
|
|
Id: parts[1],
|
|
}
|
|
dc.RackInfos = append(dc.RackInfos, rack)
|
|
} else {
|
|
rack = nil
|
|
}
|
|
case "DataNode":
|
|
if dn == nil {
|
|
dn = &master_pb.DataNodeInfo{
|
|
Id: parts[1],
|
|
DiskInfos: make(map[string]*master_pb.DiskInfo),
|
|
}
|
|
rack.DataNodeInfos = append(rack.DataNodeInfos, dn)
|
|
} else {
|
|
dn = nil
|
|
}
|
|
case "Disk":
|
|
if disk == nil {
|
|
diskType := parts[1][:strings.Index(parts[1], "(")]
|
|
volumeCountStr := parts[1][strings.Index(parts[1], ":")+1 : strings.Index(parts[1], "/")]
|
|
maxVolumeCountStr := parts[1][strings.Index(parts[1], "/")+1:]
|
|
maxVolumeCount, _ := strconv.Atoi(maxVolumeCountStr)
|
|
volumeCount, _ := strconv.Atoi(volumeCountStr)
|
|
disk = &master_pb.DiskInfo{
|
|
Type: diskType,
|
|
MaxVolumeCount: int64(maxVolumeCount),
|
|
VolumeCount: int64(volumeCount),
|
|
}
|
|
dn.DiskInfos[types.ToDiskType(diskType).String()] = disk
|
|
} else {
|
|
disk = nil
|
|
}
|
|
case "volume":
|
|
volumeLine := line[len("volume "):]
|
|
volume := &master_pb.VolumeInformationMessage{}
|
|
proto.UnmarshalText(volumeLine, volume)
|
|
disk.VolumeInfos = append(disk.VolumeInfos, volume)
|
|
case "ec":
|
|
ecVolumeLine := line[len("ec volume "):]
|
|
ecShard := &master_pb.VolumeEcShardInformationMessage{}
|
|
for _, part := range strings.Split(ecVolumeLine, " ") {
|
|
if strings.HasPrefix(part, "id:") {
|
|
id, _ := strconv.ParseInt(part[len("id:"):], 10, 64)
|
|
ecShard.Id = uint32(id)
|
|
}
|
|
if strings.HasPrefix(part, "collection:") {
|
|
ecShard.Collection = part[len("collection:"):]
|
|
}
|
|
// TODO: we need to parse EC shard sizes as well
|
|
if strings.HasPrefix(part, "shards:") {
|
|
shards := part[len("shards:["):]
|
|
shards = strings.TrimRight(shards, "]")
|
|
shardsInfo := erasure_coding.NewShardsInfo()
|
|
for _, shardId := range strings.Split(shards, ",") {
|
|
sid, _ := strconv.Atoi(shardId)
|
|
shardsInfo.Set(erasure_coding.NewShardInfo(erasure_coding.ShardId(sid), 0))
|
|
}
|
|
ecShard.EcIndexBits = shardsInfo.Bitmap()
|
|
ecShard.ShardSizes = shardsInfo.SizesInt64()
|
|
}
|
|
}
|
|
disk.EcShardInfos = append(disk.EcShardInfos, ecShard)
|
|
}
|
|
}
|
|
|
|
return topo
|
|
}
|
|
|
|
// TestWriteDataNodeInfo_SplitsCollapsedDisksByPhysicalDiskId verifies that
|
|
// the verbose Disk block in volume.list shows one entry per physical disk
|
|
// when the master collapsed several same-type disks under a single
|
|
// DiskInfos["hdd"] map entry. Before the split, six physical disks would
|
|
// appear as "Disk hdd ... id:0" with all volumes stacked on it.
|
|
func TestWriteDataNodeInfo_SplitsCollapsedDisksByPhysicalDiskId(t *testing.T) {
|
|
dn := &master_pb.DataNodeInfo{
|
|
Id: "node1:8081",
|
|
DiskInfos: map[string]*master_pb.DiskInfo{
|
|
"hdd": {
|
|
Type: "hdd",
|
|
MaxVolumeCount: 60,
|
|
VolumeInfos: []*master_pb.VolumeInformationMessage{
|
|
{Id: 1, DiskId: 0, Collection: "c"},
|
|
{Id: 2, DiskId: 1, Collection: "c"},
|
|
{Id: 3, DiskId: 2, Collection: "c"},
|
|
},
|
|
EcShardInfos: []*master_pb.VolumeEcShardInformationMessage{
|
|
{Id: 100, DiskId: 3, Collection: "c", EcIndexBits: 1},
|
|
{Id: 101, DiskId: 4, Collection: "c", EcIndexBits: 1},
|
|
{Id: 102, DiskId: 5, Collection: "c", EcIndexBits: 1},
|
|
},
|
|
},
|
|
},
|
|
}
|
|
|
|
c := &commandVolumeList{}
|
|
fs := flag.NewFlagSet("volume.list", flag.ContinueOnError)
|
|
c.collectionPattern = fs.String("collection", "", "")
|
|
c.dataCenter = fs.String("dataCenter", "", "")
|
|
c.rack = fs.String("rack", "", "")
|
|
c.dataNode = fs.String("dataNode", "", "")
|
|
c.readonly = fs.Bool("readonly", false, "")
|
|
c.writable = fs.Bool("writable", false, "")
|
|
c.volumeId = fs.Uint64("volumeId", 0, "")
|
|
|
|
var buf bytes.Buffer
|
|
verbosity := 5
|
|
rackInvocations := 0
|
|
c.writeDataNodeInfo(&buf, dn, verbosity, func() { rackInvocations++ })
|
|
|
|
out := buf.String()
|
|
// Match the "id:N\n" line ending so substring checks don't accept
|
|
// unrelated tokens like "ec volume id:101" as a match for id:1.
|
|
for diskID := 0; diskID < 6; diskID++ {
|
|
needle := fmt.Sprintf("id:%d\n", diskID)
|
|
if !strings.Contains(out, needle) {
|
|
t.Errorf("output missing %q; got:\n%s", needle, out)
|
|
}
|
|
}
|
|
|
|
// The parent's outRackInfo callback rides the same code path as the
|
|
// DataNode header — it fires from the inner writeDiskInfo callback,
|
|
// once per disk before the fix. After the fix the header guard runs
|
|
// outRackInfo at most once per DataNode. This proxy lets us pin the
|
|
// "header printed once" invariant without depending on the exact
|
|
// format of the rendered DataNode line.
|
|
if rackInvocations != 1 {
|
|
t.Errorf("DataNode header callback ran %d times; want 1 (regression: header printed once per split disk)", rackInvocations)
|
|
}
|
|
}
|
|
|
|
// volNode builds a single-node topology from (volumeId, collection) pairs so the
|
|
// duplicate-detection tests can describe a cluster compactly.
|
|
func volNode(nodeId string, volumes ...*master_pb.VolumeInformationMessage) *master_pb.DataNodeInfo {
|
|
return &master_pb.DataNodeInfo{
|
|
Id: nodeId,
|
|
DiskInfos: map[string]*master_pb.DiskInfo{
|
|
"hdd": {Type: "hdd", VolumeInfos: volumes},
|
|
},
|
|
}
|
|
}
|
|
|
|
func topoFromNodes(nodes ...*master_pb.DataNodeInfo) *master_pb.TopologyInfo {
|
|
return &master_pb.TopologyInfo{
|
|
DataCenterInfos: []*master_pb.DataCenterInfo{{
|
|
Id: "dc1",
|
|
RackInfos: []*master_pb.RackInfo{{Id: "rack1", DataNodeInfos: nodes}},
|
|
}},
|
|
}
|
|
}
|
|
|
|
// TestFindDuplicateVolumeIds covers the dangerous condition where the master
|
|
// reused a volume id across two collections (e.g. id 59788 in both infra-backup
|
|
// and ai-news-data-infrastructure) — the state that lets collection.delete
|
|
// destroy the wrong collection's data. The detector must flag exactly the shared
|
|
// ids, while same-id replicas of one volume must NOT be flagged.
|
|
func TestFindDuplicateVolumeIds(t *testing.T) {
|
|
t.Run("flags id shared across collections", func(t *testing.T) {
|
|
topo := topoFromNodes(
|
|
volNode("srv0487:8082", &master_pb.VolumeInformationMessage{Id: 59788, Collection: "infra-backup"}),
|
|
volNode("srv0502:8083", &master_pb.VolumeInformationMessage{Id: 59788, Collection: "ai-news-data-infrastructure"}),
|
|
// A clean, single-collection volume that must not be flagged.
|
|
volNode("srv0487:8085", &master_pb.VolumeInformationMessage{Id: 7069, Collection: "ai-news-data-infrastructure"}),
|
|
)
|
|
dup := findDuplicateVolumeIds(topo)
|
|
assert.Equal(t, map[uint32][]string{
|
|
59788: {"ai-news-data-infrastructure", "infra-backup"},
|
|
}, dup)
|
|
})
|
|
|
|
t.Run("replicas of one volume are not duplicates", func(t *testing.T) {
|
|
// Same id on three nodes, all the same collection: a normal replicated
|
|
// volume, not a cross-collection clash.
|
|
topo := topoFromNodes(
|
|
volNode("n1", &master_pb.VolumeInformationMessage{Id: 42, Collection: "c"}),
|
|
volNode("n2", &master_pb.VolumeInformationMessage{Id: 42, Collection: "c"}),
|
|
volNode("n3", &master_pb.VolumeInformationMessage{Id: 42, Collection: "c"}),
|
|
)
|
|
assert.Empty(t, findDuplicateVolumeIds(topo))
|
|
})
|
|
|
|
t.Run("default empty collection counts as its own collection", func(t *testing.T) {
|
|
topo := topoFromNodes(
|
|
volNode("n1", &master_pb.VolumeInformationMessage{Id: 1, Collection: ""}),
|
|
volNode("n2", &master_pb.VolumeInformationMessage{Id: 1, Collection: "x"}),
|
|
)
|
|
assert.Equal(t, map[uint32][]string{1: {"", "x"}}, findDuplicateVolumeIds(topo))
|
|
})
|
|
|
|
t.Run("normal volume and ec shard sharing an id across collections", func(t *testing.T) {
|
|
topo := topoFromNodes(volNode("n1", &master_pb.VolumeInformationMessage{Id: 5, Collection: "a"}))
|
|
topo.DataCenterInfos[0].RackInfos[0].DataNodeInfos[0].DiskInfos["hdd"].EcShardInfos =
|
|
[]*master_pb.VolumeEcShardInformationMessage{{Id: 5, Collection: "b", EcIndexBits: 1}}
|
|
assert.Equal(t, map[uint32][]string{5: {"a", "b"}}, findDuplicateVolumeIds(topo))
|
|
})
|
|
}
|
|
|
|
func TestWriteDuplicateVolumeIdWarning(t *testing.T) {
|
|
var buf bytes.Buffer
|
|
writeDuplicateVolumeIdWarning(&buf, map[uint32][]string{
|
|
59788: {"ai-news-data-infrastructure", "infra-backup"},
|
|
1: {"", "x"},
|
|
})
|
|
out := buf.String()
|
|
assert.Contains(t, out, "WARNING: 2 volume id(s) exist in more than one collection")
|
|
assert.Contains(t, out, "volume 59788 in collections: ai-news-data-infrastructure, infra-backup")
|
|
// Empty collection name is rendered readably rather than as a blank.
|
|
assert.Contains(t, out, `volume 1 in collections: "" (default), x`)
|
|
// Lowest id first.
|
|
assert.Less(t, strings.Index(out, "volume 1 "), strings.Index(out, "volume 59788 "))
|
|
|
|
// Clean topology prints nothing.
|
|
var empty bytes.Buffer
|
|
writeDuplicateVolumeIdWarning(&empty, nil)
|
|
assert.Empty(t, empty.String())
|
|
}
|